Skip to content
Shop in Mountlake TerraceCalls answered daily, 8 AM–7 PM Book online: up to $18 off the repair
LarchHVAC & Appliance (425) 570-9520
Technician beside a furnace in a utility roomFormerly Adam & Sam Brothers Repair

Electrical license · 06A

The 06A license behind our furnace and heat pump work

Our electrical contractor license in the (06A) HVAC/refrigeration specialty is the state's go-ahead for the electrical side of heating, cooling and refrigeration work. This page covers what Washington's rule allows, what it leaves to other electricians, and how permits fit in.

06A HVAC/Refrigeration

Electrical Contractor — (06A) HVAC/Refrigeration

No. LARCHHA742PL

  • Valid through Oct 26, 2028
  • Name on the L&I record: LARCH HVAC & APPLIANCE

L&I issues this electrical contractor license in the (06A) HVAC/refrigeration specialty. It covers line-voltage work inside heating, cooling and refrigeration equipment, the low-voltage control wiring that ties a system together, and the short supply whip at the unit. It is valid anywhere in Washington.

Verify on L&I

What the 06A specialty is

Washington licenses electrical contractors either in general (01), which reaches every type of electrical installation, or in one of the narrower specialties listed in WAC 296-46B-920. Specialty 06A is HVAC/refrigeration. The state's definitions call the central unit of the system the equipment, naming heat pumps, furnaces and compressor packages among others, and treat the motors, compressors, heating coils, controls, switches and thermostats within it as its components.

The license comes with obligations. A Washington electrical contractor must have an assigned electrical administrator or master electrician who answers for compliance with state electrical law, and an administrator who holds a specialty can only be assigned to a contractor in that same specialty. The rule also bars an unsupervised electrical trainee from working on any part of an HVAC/refrigeration system with a circuit rated over 600 volts.

What 06A covers, in plain words

Unlike most specialties, 06A is not capped by voltage, phase or amperage, so the same license applies to a 120-volt ductless head and a three-phase condensing unit behind a restaurant. Within the HVAC/refrigeration system, the rule allows:

  • Line-voltage components inside the equipment: blower and inducer motors, compressors, contactors, capacitors, heat strips, control boards, plus product lighting the unit powers, like the lights in a reach-in beverage cooler.
  • Low-voltage control wiring in every residential occupancy, such as thermostat cable and the control run to an outdoor unit.
  • Short pieces of raceway that protect low-voltage cable, provided they do not join two boxes or devices.
  • Flexible line-voltage supply whips up to six feet, with no change to the branch circuit.
  • The internal parts of the equipment's disconnect or controller, unless it sits in a panelboard or motor control center.

That lines up with most of our calls: furnace repair and replacement, AC and heat pump work, ductless mini-splits, tune-ups and commercial refrigeration.

What the license means when we work on your system

Under state rules, electrical work needs a permit unless a specific exemption applies, and the permit must be in hand before the work begins. For a like-in-kind replacement on the existing branch circuit, a licensed electrical contractor can use L&I's Class B label instead: it covers a furnace up to 240 volts and 100 amps, or a heat pump or air conditioner up to 240 volts and 40 minimum circuit amps, and those jobs are inspected at random. A new installation goes through a regular electrical work permit, with the inspection request due within three working days of finishing or one working day after any part is energized, whichever comes first.

Your address decides which office handles it. Seattle, Everett, Lynnwood, Kirkland and Mountlake Terrace run their own electrical permits and inspections, and L&I does not issue permits inside those cities. Seattle adds a furnace permit for any furnace replacement or alteration, and a refrigeration permit for any split-system heat pump or air conditioner; only a licensed refrigeration contractor can obtain that one.

Where 06A stops

The specialty ends at the equipment and its controls. It excludes line-voltage controllers and disconnect switches mounted outside the unit, with one narrow exception: when the equipment itself is replaced, a surface-mounted disconnect enclosure rated no higher than 20-amp, 120-volt may be swapped like for like on the existing wiring method. Also outside 06A, with narrow exceptions: stand-alone line-voltage equipment such as baseboard or wall heaters and heat cable, conduit systems, service, feeder and branch-circuit conductors, panelboards, building lighting, and wiring in classified hazardous locations outside the equipment.

In practice, a first-time mini-split or heat pump that needs a dedicated 240-volt circuit and a new outdoor disconnect, or a panel with no room for another breaker, is a job for a general (01) electrical contractor, priced on its own line apart from our install. We look at the circuit, breaker and disconnect during the site visit so that surfaces early rather than on install day.

Checking our 06A license yourself

On L&I Verify, choose the WA UBI No. search and enter 605283205. Open the electrical contractor record and look for HVAC/refrigeration (06A) under License specialties, with its effective and expiration dates; that record is filed as LARCH HVAC & APPLIANCE, while records from before our 2026 name change carry the former name, ADAM&SAM BROTHERS REPAIR. Below that, License Violations lists any citations. Verify also lets you look up an individual electrician's certificate if you want to check the technician at your door.

Two details explain what you will and will not see. State law sets the electrical contractor bond at $4,000, and L&I does not keep liability insurance records for electrical contractors, so our insurance appears under the construction contractor registration described on the general contractor page. All three credentials are summarized on our licenses page.

Licensing and permit guides

Common questions

Does the 06A license cover ductless mini-splits?

Yes. A mini-split is HVAC/refrigeration equipment, so its internal electrical components, low-voltage controls and supply whip fall under 06A. What often does not is the new circuit and outdoor disconnect a first install needs; those belong to a general (01) electrical contractor. When a suitable circuit and disconnect already exist, as on many replacements, the electrical side stays within our specialty.

Will an inspector come out after you replace my furnace?

It depends on the job and the city. A like-for-like furnace swap on the existing circuit can run under L&I's Class B label, and those jobs are inspected at random, so a visit is possible but not certain. A new installation gets a regular permit and inspection. In Seattle the city's own furnace permit applies, with a cover inspection before anything is closed up and a final inspection after.

Can you replace the thermostat and run new thermostat wire?

Yes. Low-voltage control wiring is part of 06A in every residential occupancy, so swapping a thermostat or pulling new cable for a heat pump or a second heating stage is inside the specialty. A line-voltage thermostat that runs baseboard heaters on their own is different, because stand-alone heaters and their controls sit outside 06A.

Does 06A apply to a restaurant walk-in or reach-in?

It does. The rule covers refrigeration systems, including lighting that a reach-in cooler or frozen food case powers from its own equipment, and it carries no single-phase or voltage cap. The building's panels and feeders, and wiring in classified locations under NEC articles 500 to 516 outside the equipment, still belong to a general electrical contractor.

Can a trainee work on my system?

Washington allows electrical trainees, and the 06A rule adds a firm limit for this trade: no unsupervised trainee may install, repair, replace or maintain any part of an HVAC/refrigeration system with a circuit over 600 volts. Household heating and cooling equipment runs well below that, but larger commercial systems can exceed it, and there the limit applies.

Talk to Adam & Sam

Planning a furnace, heat pump or mini-split replacement and wondering how the permit works at your address? Call (425) 570-9520, or book a site visit online.

Schedule a repair

Request a visit from Adam & Sam

Send the basics and we call you back with an arrival window, most days the same morning.

  • Diagnostic inside the repair The office names the fee when you call or book. It becomes part of the repair price when you say yes; pass on the repair and it is all you pay.
  • Up to $18 off Any repair requested through the online form. The diagnostic itself is never reduced.
  • $10 off A second appliance’s diagnostic when we check it during the same trip.

Requests sent from this form get up to $18 off the repair. The diagnostic stays the same and is folded into any repair you approve.

CallBook